Share:

FAU 2 over SOUTH CHICKAMAUGA CREEK

Map

Coordinates:
+35.01500, -85.21000
35°00'54" N, 85°12'36" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:FAU 2 over SOUTH CHICKAMAUGA CREEK
Structure number:33SR0020023
Location:2.01 MI. W OF SR-153 JCT.
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:86.9 ft. [26.5 m]
Total length:414.1 ft. [126.2 m]
Roadway width between curbs:88.6 ft. [27.0 m]
Deck width edge-to-edge:96.8 ft. [29.5 m]
Skew angle:10°
Owner:State Highway Agency [01]
Year built:1993
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Prestressed concrete continuous [6]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: November 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:34,580 [as of 2015]
Truck traffic:2% of total traffic
Deck condition:Very Good [8 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Very Good [8 out of 9]
Structural appraisal:Equal to present desirable criteria [8]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:64.4 tons [58.5 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:82.0

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
November 201682.0GoodVery GoodVery GoodVery Good-34580
November 201482.0GoodVery GoodVery GoodVery Good-32330
November 201282.0GoodGoodGoodGood-36020
November 201084.0GoodGoodGoodGood-38220
November 200884.0GoodGoodGoodGood-37050
November 200684.0GoodGoodGoodGood-38350
January 200584.0GoodGoodGoodGood-38100
October 200284.0GoodGoodGoodGood-35440
November 200084.0GoodGoodGoodGood-36370
October 199884.0GoodGoodGoodGood-40210
November 199684.0GoodGoodGoodGood-28790
June 199584.0GoodGoodGoodGood-24550
March 199484.0GoodGoodGoodGood-22830
May 199344.5FairFairFairFairFO34880
April 199144.5FairFairFairFairFO34150