FAS 114 over TENNESSEE RIVER
Map
Coordinates:
+35.40550, -88.0562835°24'20" N, 88°03'23" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FAS 114 over TENNESSEE RIVER |
Structure number: | 36SR1140001 |
Location: | 3 MI. S. WAYNE CO. LINE |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 525.0 ft. [160.0 m] |
Total length: | 2893.5 ft. [881.9 m] |
Roadway width between curbs: | 47.9 ft. [14.6 m] |
Deck width edge-to-edge: | 49.9 ft. [15.2 m] |
Vertical clearance below bridge: | 49.2 ft. [15.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1997 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Precast Panels [2] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2018
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 2,180 [as of 2017] |
Truck traffic: | 6% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Water adequacy appraisal: | Equal to present desirable criteria [8] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Pier/abutment protection: | Navigation protection not required [1] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 85.5 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2018 | Fair | Satisfactory | Satisfactory | Satisfactory | 2180 | 85.5 |
June 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 1920 | 86.8 |
July 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 1800 | 87.4 |
July 2012 | Fair | Satisfactory | Satisfactory | Good | 1640 | 88.3 |
August 2010 | Fair | Satisfactory | Satisfactory | Good | 2040 | 86.2 |
July 2008 | Fair | Satisfactory | Good | Good | 1870 | 87.1 |
August 2006 | Fair | Fair | Good | Good | 1850 | 86.1 |
October 2004 | Fair | Fair | Good | Good | 1800 | 86.3 |
December 2002 | Fair | Fair | Good | Good | 1610 | 87.3 |
January 2001 | Fair | Fair | Very Good | Good | 2070 | 84.9 |
November 1998 | Fair | Fair | Very Good | Good | 960 | 92.7 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 6,028 | 6,028 | 0 | 0 | 0 |
Prestressed Concrete Girder/Beam | linear ft. | 10,130 | 9,859 | 241 | 30 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 145,845 | 144,845 | 1,000 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 15 | 15 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 100 | 100 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 720 | 720 | 0 | 0 | 0 |
Joints |
Strip Seal Joint | linear ft. | 152 | 152 | 0 | 0 | 0 |
Bearings |
Movable Bearing | each | 15 | 15 | 0 | 0 | 0 |
Fixed Bearing | each | 5 | 5 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 5,788 | 5,788 | 0 | 0 | 0 |