Share:

I40 over THIRD CREEK

Map

Coordinates:
+35.95500, -83.97167
35°57'18" N, 83°58'18" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:I40 over THIRD CREEK
Structure number:47I00400039
Location:4 M SW OF I75
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Interstate (Urban) [11]
Length of largest span:12.1 ft. [3.7 m]
Total length:40.0 ft. [12.2 m]
Owner:State Highway Agency [01]
Year built:1965
Year reconstructed:1981
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:193,910 [as of 2015]
Truck traffic:15% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:59.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$736,000

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
December 201659.0Fair5 out of 10-193910
February 201559.0Fair5 out of 10-182560
February 201359.0Fair5 out of 10-178240
February 201159.0Fair5 out of 10-178800
March 200859.0Fair5 out of 10-173580
November 200659.0Fair5 out of 10-155790
January 200559.0Fair5 out of 10-154890
March 200359.0Fair5 out of 10-150020
November 200059.0Fair5 out of 10-140170
October 199859.0Fair5 out of 10-163220
October 199659.0Fair5 out of 10-156960
November 199470.0Fair6 out of 10-123610
October 199270.0Fair6 out of 10-109000
October 199070.0Fair6 out of 10-109000