Facts 

Name:FAU 1250 (SA 4706) over FOURTH CREEK
Structure number:47S25020001
Location:.10 M W OF SR332
Purpose:Carries highway over waterway
Route classification:Collector (Urban) [17]
Length of largest span:12.1 ft. [3.7 m]
Total length:38.1 ft. [11.6 m]
Roadway width between curbs:65.9 ft. [20.1 m]
Deck width edge-to-edge:69.6 ft. [21.2 m]
Owner:City or Municipal Highway Agency [04]
Year built:1965
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2016 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,250 [as of 2017]
Truck traffic:2% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:42.8 tons [38.9 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:88.7

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 201688.7Fair6 out of 10-9250
June 201488.7Fair6 out of 10-9250
June 201288.7Fair6 out of 10-9250
June 201088.7Fair6 out of 10-9250
June 200888.7Fair6 out of 10-9250
June 200685.8Fair6 out of 10-9120
May 200485.8Fair6 out of 10-9130
May 200285.4Fair6 out of 10-9860
May 200085.6Fair6 out of 10-6950
June 199885.8Fair6 out of 10-6570
January 199666.9Fair6 out of 10-8600
September 199366.7Good7 out of 10-9000
October 199167.7Good7 out of 10-7100