Share:

FAP 33 over SR 33/SR331(TAZEWELL PK)

Map

Coordinates:
+36.02194, -83.92417
36°01'19" N, 83°55'27" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAP 33 over SR 33/SR331(TAZEWELL PK)
Structure number:47SR0330029
Location:4 M SE OF KNOXVILLE
Purpose:Carries highway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:92.9 ft. [28.3 m]
Total length:195.2 ft. [59.5 m]
Roadway width between curbs:89.9 ft. [27.4 m]
Deck width edge-to-edge:92.5 ft. [28.2 m]
Vertical clearance below bridge:14.4 ft. [4.4 m]
Owner:State Highway Agency [01]
Year built:1971
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: December 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:45,120 [as of 2015]
Truck traffic:8% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:53.5 tons [48.6 metric tons]
Inventory rating:32.7 tons [29.7 metric tons]
Sufficiency rating:96.6

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201596.6FairGoodGoodSatisfactory-45120
December 201396.6FairGoodGoodSatisfactory-41460
January 201296.6FairGoodGoodSatisfactory-41470
February 201098.0GoodGoodGoodGood-42000
February 200899.0GoodGoodGoodGood-42680
February 200698.0FairFairGoodSatisfactory-43830
February 200499.0FairSatisfactoryGoodSatisfactory-42500
October 200199.0FairSatisfactoryGoodSatisfactory-41430
November 199994.0FairSatisfactoryGoodSatisfactoryFO41990
February 199894.0FairSatisfactoryGoodSatisfactoryFO65500
October 199594.0FairSatisfactoryGoodSatisfactoryFO61200
October 199389.9FairSatisfactoryGoodSatisfactoryFO59400
December 199189.9FairSatisfactoryGoodSatisfactoryFO50600
January 199092.9FairSatisfactoryGoodSatisfactory-50600

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.1,9501,949100
Steel Protective Coatingsq. ft.17,38717,387000
Deck
Reinforced Concrete Decksq. ft.17,94016,97896200
Substructure
Reinforced Concrete Columneach2017300
Reinforced Concrete Abutmentlinear ft.1841384600
Joints
Strip Seal Jointlinear ft.1841384600
Bearings
Movable Bearingeach4040000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.390390000
Reinforced Concrete Bridge Raillinear ft.39019519500