Share:

FAP 115 RL over LITTLE RIVER

Map

Coordinates:
+35.87306, -83.95889
35°52'23" N, 83°57'32" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAP 115 RL over LITTLE RIVER
Structure number:47SR1150001
Location:.04 MI N. OF BLOUNT CO. L
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:68.9 ft. [21.0 m]
Total length:484.6 ft. [147.7 m]
Roadway width between curbs:58.1 ft. [17.7 m]
Deck width edge-to-edge:65.0 ft. [19.8 m]
Owner:State Highway Agency [01]
Year built:2005
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:49,820 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:There are no noticeable or noteworthy deficiencies which affect the condition of the channel. [9]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:95.0 tons [86.4 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:95.3

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201695.3GoodGoodGoodGood-49820
February 201495.8GoodVery GoodVery GoodVery Good-45320
February 201295.5GoodVery GoodVery GoodVery Good-47820
March 201095.7GoodVery GoodExcellentExcellent-46170
April 200895.5GoodVery GoodExcellentExcellent-47750
March 200695.1GoodVery GoodExcellentExcellent-52340
February 200474.6GoodExcellentExcellentExcellentFO53350
December 200174.6FairSatisfactorySatisfactorySatisfactoryFO52670
November 199975.0FairGoodSatisfactoryGoodFO49340
March 199875.0FairGoodSatisfactoryGoodFO49500
October 199576.6FairGoodSatisfactoryGoodFO45340
June 199476.6FairGoodSatisfactoryGoodFO45190
March 199275.8GoodGoodGoodGoodFO53880
March 199075.8GoodGoodGoodGoodFO53880

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.3,8773,8641300
Deck
Reinforced Concrete Decksq. ft.31,54731,5074000
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.1301121800
Reinforced Concrete Pier Caplinear ft.390390000
Joints
Strip Seal Jointlinear ft.1301042600
Bearings
Elastomeric Bearingeach6464000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.485485000
Reinforced Concrete Bridge Raillinear ft.96967929000