Share:

FAP 115 over SR158 / SR115 RAMP B

Map

Coordinates:
+35.95000, -83.94222
35°57'00" N, 83°56'32" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAP 115 over SR158 / SR115 RAMP B
Structure number:47SR1150029
Location:1.4 MI N. OF BLOUNT CO. L
Purpose:Carries highway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:125.0 ft. [38.1 m]
Total length:201.1 ft. [61.3 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:32.2 ft. [9.8 m]
Vertical clearance below bridge:16.7 ft. [5.1 m]
Owner:State Highway Agency [01]
Year built:2001
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:15,390 [as of 2015]
Truck traffic:5% of total traffic
Deck condition:Excellent [9 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Operating rating:82.2 tons [74.7 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:98.6

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
February 201698.6GoodExcellentGoodGood-15390
February 201498.5GoodExcellentGoodGood-16210
February 201298.6GoodExcellentGoodGood-14700
March 201098.4GoodExcellentGoodGood-17130
April 200898.3GoodExcellentGoodGood-17730
March 200690.6GoodExcellentGoodExcellent-55400
February 200490.7GoodExcellentExcellentExcellent-54180
November 200194.8GoodExcellentExcellentExcellent-55070

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Steel Girder/Beamlinear ft.804804000
Steel Protective Coatingsq. ft.8,1828,182000
Deck
Reinforced Concrete Decksq. ft.6,4326,4023000
Substructure
Reinforced Concrete Columneach21010
Reinforced Concrete Abutmentlinear ft.128116840
Reinforced Concrete Pier Caplinear ft.6464000
Joints
Strip Seal Jointlinear ft.64521200
Bearings
Enclosed/Concealed Bearingeach2424000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4023604020