Share:

FAU 131 over BRANCH

Map

Coordinates:
+36.05556, -83.98722
36°03'20" N, 83°59'14" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts

Name:FAU 131 over BRANCH
Structure number:47SR1310009
Location:1 MI NE OF I75
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:12.1 ft. [3.7 m]
Total length:25.9 ft. [7.9 m]
Owner:State Highway Agency [01]
Year built:2008
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:16,870 [as of 2015]
Truck traffic:7% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:59.5 tons [54.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:70.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$301,000

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
February 201670.0Good7 out of 10-16870
February 201470.0Good8 out of 10-15200
February 201270.0Good8 out of 10-16490
February 201170.0Good8 out of 10-14840
December 200967.0Good8 out of 10-13650
September 200867.0Good8 out of 10-12540