FAP 29 over WEBB CREEK
Map
Coordinates:
+36.31455, -84.6269536°18'52" N, 84°37'37" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FAP 29 over WEBB CREEK |
Structure number: | 76SR0290001 |
Location: | 2.1 MI SW SR52 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 41.3 ft. [12.6 m] |
Total length: | 43.0 ft. [13.1 m] |
Roadway width between curbs: | 34.8 ft. [10.6 m] |
Deck width edge-to-edge: | 38.4 ft. [11.7 m] |
Skew angle: | 20° |
Owner: | State Highway Agency [01] |
Year built: | 1925 |
Year reconstructed: | 1989 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | M 13.5 / H 15 [2] |
Main span material: | Concrete [1] |
Main span design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 1,870 [as of 2017] |
Truck traffic: | 22% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Equal to present minimum criteria [6] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 80.0 |
Recommended work: | Bridge rehabilitation because of general structure deterioration or inadequate strength. [35] |
Estimated cost of work: | $428,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Good | Satisfactory | Satisfactory | 1870 | 80.0 |
April 2015 | Fair | Good | Satisfactory | Satisfactory | 1860 | 80.0 |
April 2013 | Fair | Good | Satisfactory | Satisfactory | 1950 | 80.0 |
April 2011 | Fair | Good | Satisfactory | Satisfactory | 2140 | 79.0 |
April 2009 | Fair | Good | Satisfactory | Satisfactory | 2120 | 79.0 |
March 2007 | Fair | Satisfactory | Satisfactory | Satisfactory | 2380 | 77.0 |
April 2005 | Fair | Satisfactory | Satisfactory | Satisfactory | 2410 | 79.0 |
April 2003 | Fair | Satisfactory | Satisfactory | Satisfactory | 2230 | 79.0 |
April 2001 | Fair | Satisfactory | Satisfactory | Satisfactory | 2250 | 79.0 |
March 1999 | Fair | Satisfactory | Satisfactory | Satisfactory | 2240 | 79.0 |
April 1997 | Fair | Satisfactory | Satisfactory | Satisfactory | 2230 | 79.0 |
March 1995 | Fair | Satisfactory | Satisfactory | Satisfactory | 2020 | 78.0 |
January 1993 | Fair | Satisfactory | Satisfactory | Satisfactory | 1900 | 79.0 |
March 1991 | Fair | Satisfactory | Satisfactory | Fair | 1890 | 48.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Prestressed Concrete Closed Web/Box Girder | linear ft. | 86 | 86 | 0 | 0 | 0 |
Reinforced Concrete Girder/Beam | linear ft. | 215 | 206 | 4 | 5 | 0 |
Deck |
Reinforced Concrete Deck | sq. ft. | 613 | 613 | 0 | 0 | 0 |
Reinforced Concrete Top Flange | sq. ft. | 1,021 | 955 | 0 | 23 | 43 |
Wearing Surfaces | sq. ft. | 1,021 | 202 | 0 | 819 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 78 | 55 | 11 | 12 | 0 |
Bearings |
Elastomeric Bearing | each | 4 | 4 | 0 | 0 | 0 |
Bridge Rail |