FAP 29 over SOU RWY & NFA A168
Map
Coordinates:
+36.47673, -84.5394336°28'36" N, 84°32'22" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FAP 29 over SOU RWY & NFA A168 |
Structure number: | 76SR0290035 |
Location: | IN THE CITY OF ONEIDA |
Purpose: | Carries highway over highway and railroad |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 148.0 ft. [45.1 m] |
Total length: | 497.1 ft. [151.5 m] |
Roadway width between curbs: | 86.0 ft. [26.2 m] |
Deck width edge-to-edge: | 87.9 ft. [26.8 m] |
Vertical clearance below bridge: | 13.1 ft. [4.0 m] |
Owner: | State Highway Agency [01] |
Year built: | 1996 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 4 |
Main spans material: | Steel continuous [4] |
Main spans design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: April 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 12,280 [as of 2017] |
Truck traffic: | 7% of total traffic |
Deck condition: | Good [7 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Superior to present desirable criteria [9] |
Underclearances appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Scour condition: | Bridge not over waterway. [N] |
Sufficiency rating: | 84.2 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
April 2017 | Fair | Good | Satisfactory | Satisfactory | 12280 | 84.2 |
April 2015 | Fair | Good | Satisfactory | Satisfactory | 12660 | 83.8 |
April 2013 | Fair | Good | Satisfactory | Satisfactory | 11960 | 84.5 |
April 2011 | Good | Good | Very Good | Good | 13560 | 83.0 |
April 2009 | Good | Good | Very Good | Good | 14570 | 83.0 |
April 2007 | Good | Very Good | Very Good | Good | 13520 | 83.0 |
April 2005 | Good | Very Good | Very Good | Good | 13720 | 85.0 |
April 2003 | Good | Very Good | Very Good | Good | 12550 | 85.9 |
April 2001 | Good | Very Good | Very Good | Good | 12130 | 86.4 |
April 1999 | Good | Very Good | Very Good | Good | 12760 | 85.0 |
April 1997 | Good | Excellent | Excellent | Excellent | 9560 | 87.2 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Steel Girder/Beam | linear ft. | 3,976 | 3,926 | 50 | 0 | 0 |
Steel Protective Coating | sq. ft. | 50,766 | 48,228 | 0 | 0 | 2,538 |
Deck |
Reinforced Concrete Deck | sq. ft. | 43,736 | 43,636 | 100 | 0 | 0 |
Substructure |
Reinforced Concrete Column | each | 8 | 8 | 0 | 0 | 0 |
Reinforced Concrete Abutment | linear ft. | 176 | 148 | 22 | 6 | 0 |
Steel Pier Cap | linear ft. | 88 | 88 | 0 | 0 | 0 |
Steel Protective Coating | sq. ft. | 1,144 | 1,144 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 176 | 176 | 0 | 0 | 0 |
Joints |
Assembly with Seal | each | 88 | 16 | 0 | 72 | 0 |
Bearings |
Movable Bearing | each | 26 | 16 | 10 | 0 | 0 |
Enclosed/Concealed Bearing | each | 8 | 8 | 0 | 0 | 0 |
Fixed Bearing | each | 2 | 2 | 0 | 0 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 994 | 0 | 985 | 9 | 0 |