Facts 

Name:FAU 2842 over DITCH
Structure number:79028420007
Location:NEW HORN LAKE RD-MEMPHIS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:13.1 ft. [4.0 m]
Total length:44.0 ft. [13.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1977
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: March 2017 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:12,920 [as of 2017]
Truck traffic:8% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:71.7
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$715,000

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
March 201771.7Fair6 out of 10-12920
April 201571.7Fair6 out of 10-12920
April 201371.7Fair6 out of 10-12920
May 201171.7Fair6 out of 10-12920
June 200971.7Fair6 out of 10-12920
October 200771.7Fair6 out of 10-12920
October 200571.9Fair6 out of 10-12670
October 200370.8Fair6 out of 10-14090
November 200169.8Fair6 out of 10-15280
March 200069.7Fair6 out of 10-15450
June 199873.1Fair6 out of 10-14910
November 199569.2Good7 out of 10-16120
October 199369.4Good7 out of 10-15320
December 199169.4Good7 out of 10-15330