Share:

FAU 2861 over CYPRESS CREEK

Map 

Coordinates:
+35.11528, -89.96889
35°06'55" N, 89°58'08" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FAU 2861 over CYPRESS CREEK
Structure number:79028610003
Location:SOUTHERN AVE - MEMPHIS
Purpose:Carries highway and pedestrian walkway over waterway
Route classification:Minor Arterial (Urban) [16]
Length of largest span:6.9 ft. [2.1 m]
Total length:34.1 ft. [10.4 m]
Owner:City or Municipal Highway Agency [04]
Year built:1960
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Not applicable [N]

Latest Available Inspection: March 2017 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:9,930 [as of 2017]
Truck traffic:9% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:73.0
Recommended work:Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Estimated cost of work:$496,000

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
March 201773.0Fair6 out of 10-9930
April 201573.0Good7 out of 10-9930
April 201373.0Good7 out of 10-9930
May 201173.0Good7 out of 10-9930
June 200973.0Good7 out of 10-9930
October 200773.0Good7 out of 10-9930
October 200572.1Good7 out of 10-10880
October 200372.7Good7 out of 10-10250
November 200172.3Good7 out of 10-10690
March 200072.2Good7 out of 10-10810
June 199870.9Good7 out of 10-12170
November 199567.0Good7 out of 10-19350
October 199367.0Good7 out of 10-19000
December 199168.6Good7 out of 10-14700