NFA D378 over BRANCH
Map
Coordinates:
+35.19250, -89.9094435°11'33" N, 89°54'34" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.
Facts
Name: | NFA D378 over BRANCH |
Structure number: | 790D3780001 |
Location: | JOHN F KENNEDY PARK |
Purpose: | Carries highway over waterway |
Route classification: | Local (Urban) [19] |
Length of largest span: | 12.1 ft. [3.7 m] |
Total length: | 26.9 ft. [8.2 m] |
Roadway width between curbs: | 29.5 ft. [9.0 m] |
Deck width edge-to-edge: | 32.2 ft. [9.8 m] |
Owner: | Local Park, Forest, or Reservation Agency [12] |
Year built: | 1980 |
Historic significance: | Historical significance is not determinable at this time [4] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 2 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Culvert [19] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: May 2015
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 100 [as of 2016] |
Truck traffic: | 2% of total traffic |
Structural appraisal: | Better than present minimum criteria [7] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Better than present minimum criteria [7] |
Roadway alignment appraisal: | Equal to present minimum criteria [6] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Operating rating: | 74.8 tons [68.0 metric tons] |
Inventory rating: | 35.6 tons [32.4 metric tons] |
Sufficiency rating: | 94.1 |
Previous Inspections
Date | Suff. Rating | Condition | Culvert Condition | SD/FO | ADT |
---|
May 2015 | 94.1 | Good | 7 out of 10 | - | 100 |
May 2013 | 91.1 | Good | 7 out of 10 | - | 100 |
June 2011 | 91.1 | Good | 7 out of 10 | - | 100 |
August 2009 | 91.1 | Good | 7 out of 10 | - | 100 |
November 2007 | 91.1 | Good | 7 out of 10 | - | 100 |
November 2005 | 91.1 | Good | 7 out of 10 | - | 100 |
November 2003 | 91.1 | Good | 7 out of 10 | - | 100 |
December 2001 | 91.1 | Good | 7 out of 10 | - | 100 |
April 2000 | 91.1 | Good | 7 out of 10 | - | 100 |
April 1998 | 90.0 | Good | 7 out of 10 | FO | 100 |