Share:

FAU 277 732185F over SR277 / 2861, E295 & RR

Map

Coordinates:
+35.11525, -89.98436
35°06'55" N, 89°59'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAU 277 732185F over SR277 / 2861, E295 & RR
Structure number:79FA3120003
Location:0.7 MI. N OF SR-4 JCT.
Purpose:Carries highway and pedestrian walkway over highway and railroad
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:43.0 ft. [13.1 m]
Total length:679.2 ft. [207.0 m]
Roadway width between curbs:60.0 ft. [18.3 m]
Deck width edge-to-edge:74.2 ft. [22.6 m]
Vertical clearance below bridge:19.7 ft. [6.0 m]
Owner:State Highway Agency [01]
Year built:1947
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:23
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:24,340 [as of 2015]
Truck traffic:3% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of replacement [2]
Underclearances appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:80.9
Recommended work:Widening of existing bridge or other major structure without deck rehabilitation or replacement [33]
Estimated cost of work:$2,491,000

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017FairSatisfactorySatisfactorySatisfactory2434080.9
March 2015FairSatisfactorySatisfactorySatisfactory2310081.4
March 2013FairSatisfactorySatisfactorySatisfactory2354081.3
April 2011FairSatisfactorySatisfactorySatisfactory2230081.8
May 2009FairSatisfactorySatisfactorySatisfactory2417081.0
September 2007FairSatisfactorySatisfactorySatisfactory2569078.4
September 2005FairFairFairFair2818066.8
October 2003FairFairFairFair2852066.6
October 2001FairFairFairFair3091065.5
March 2000----121700.0
March 1998FairFairFairFair2675069.8
October 1995FairSatisfactoryFairSatisfactory3092062.0
September 1993FairSatisfactoryFairSatisfactory3763062.0
December 1991FairSatisfactoryFairSatisfactory3559062.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,6801,679100
Reinforced Concrete Girder/Beamlinear ft.5,1305,0953500
Deck
Reinforced Concrete Decksq. ft.50,58650,583300
Wearing Surfacessq. ft.50,58650,5751100
Substructure
Reinforced Concrete Columneach44311300
Reinforced Concrete Abutmentlinear ft.149148100
Reinforced Concrete Pier Caplinear ft.1,6391,52411500
Joints
Strip Seal Jointlinear ft.120012000
Bearings
Elastomeric Bearingeach130130000
Movable Bearingeach88000
Bridge Rail
Other Material Bridge Raillinear ft.1,3681,368000