Share:

FAU 2813 over WINCHESTER RD / I-55

Map

Coordinates:
+35.05381, -90.01353
35°03'14" N, 90°00'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAU 2813 over WINCHESTER RD / I-55
Structure number:79I00550023
Location:WINCHESTER RD - MEMPHIS
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:115.2 ft. [35.1 m]
Total length:232.0 ft. [70.7 m]
Roadway width between curbs:87.9 ft. [26.8 m]
Deck width edge-to-edge:102.0 ft. [31.1 m]
Vertical clearance below bridge:13.1 ft. [4.0 m]
Skew angle:32°
Owner:State Highway Agency [01]
Year built:2000
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Steel continuous [4]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:21,590 [as of 2017]
Truck traffic:4% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:89.7

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
January 2017FairSatisfactoryVery GoodGood2159089.7
February 2015GoodGoodVery GoodGood2159088.6
February 2013GoodGoodVery GoodGood2159088.6
March 2011GoodGoodVery GoodGood2159088.6
April 2009GoodGoodVery GoodGood2159088.6
June 2007GoodGoodVery GoodGood2159090.8
August 2005GoodGoodVery GoodGood2341090.1
August 2003GoodVery GoodVery GoodGood2521085.0
July 2001GoodVery GoodVery GoodVery Good2645087.8
January 2000FairSatisfactoryGoodGood2459077.7
June 1998GoodGoodGoodGood2693076.7
August 1995FairSatisfactorySatisfactoryGood2837061.9
August 1993FairSatisfactorySatisfactoryGood2821062.9
November 1991FairSatisfactoryGoodGood2467064.7

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.2,7842,784000
Steel Protective Coatingsq. ft.2,7842,784000
Deck
Reinforced Concrete Decksq. ft.23,66423,664000
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.266266000
Reinforced Concrete Pier Caplinear ft.133133000
Bearings
Fixed Bearingeach1212000
Steel Protective Coatingsq. ft.1212000