Share:

FAP 3 over TODD CREEK

Map

Coordinates:
+35.23372, -90.01619
35°14'01" N, 90°00'58" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAP 3 over TODD CREEK
Structure number:79SR0030032
Location:.2 M S OF SR 388
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:28.5 ft. [8.7 m]
Total length:57.1 ft. [17.4 m]
Roadway width between curbs:31.8 ft. [9.7 m]
Deck width edge-to-edge:43.0 ft. [13.1 m]
Owner:State Highway Agency [01]
Year built:1956
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 18 / H 20 [4]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:27,940 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Sufficiency rating:93.6

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017FairSatisfactoryGoodSatisfactory2794093.6
March 2015FairSatisfactoryGoodSatisfactory2745093.7
February 2013FairSatisfactoryGoodSatisfactory2758094.7
May 2011FairSatisfactoryGoodSatisfactory3201094.5
May 2009FairSatisfactoryGoodSatisfactory3133094.5
August 2007FairSatisfactoryGoodSatisfactory3176094.5
August 2005FairSatisfactoryGoodSatisfactory3124094.5
September 2003FairSatisfactoryGoodSatisfactory3174094.5
October 2001FairSatisfactoryGoodSatisfactory3188093.5
February 2000FairSatisfactoryGoodSatisfactory2554089.7
February 1998FairSatisfactoryGoodSatisfactory2355091.8
September 1995PoorSatisfactorySatisfactoryPoor2265064.5
August 1993PoorSatisfactorySatisfactoryPoor2265064.5

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.399399000
Deck
Prestressed Concrete Decksq. ft.2,4512,451000
Substructure
Reinforced Concrete Pier Walllinear ft.4343000
Reinforced Concrete Abutmentlinear ft.8686000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.5757000