Share:

FAP 3 over LOOSAHATCHIE RIVER

Map

Coordinates:
+35.25917, -89.99417
35°15'33" N, 89°59'39" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAP 3 over LOOSAHATCHIE RIVER
Structure number:79SR0030038
Location:1.21 M FM FITE RD
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:75.1 ft. [22.9 m]
Total length:329.4 ft. [100.4 m]
Roadway width between curbs:42.0 ft. [12.8 m]
Deck width edge-to-edge:44.0 ft. [13.4 m]
Owner:State Highway Agency [01]
Year built:1956
Year reconstructed:1989
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete continuous [2]
Main spans design:Tee beam [04]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: December 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:17,890 [as of 2015]
Truck traffic:10% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present desirable criteria [8]
Water adequacy appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:40.6 tons [36.9 metric tons]
Inventory rating:24.8 tons [22.5 metric tons]
Sufficiency rating:76.7

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
December 201676.7FairSatisfactorySatisfactoryFair-17890
June 201586.9FairSatisfactorySatisfactorySatisfactory-17890
June 201386.8FairSatisfactorySatisfactorySatisfactory-19180
June 201186.8FairSatisfactorySatisfactorySatisfactory-19220
July 200987.8FairSatisfactorySatisfactorySatisfactory-20590
July 200785.6FairSatisfactorySatisfactorySatisfactory-22930
July 200575.5FairSatisfactorySatisfactoryFair-22240
July 200375.4FairSatisfactorySatisfactoryFair-23750
August 200187.6FairSatisfactorySatisfactorySatisfactory-23590
September 199985.5FairSatisfactorySatisfactorySatisfactory-25540
February 199878.3FairSatisfactorySatisfactorySatisfactory-23300
September 199577.8FairSatisfactorySatisfactorySatisfactory-23550
August 199377.7FairSatisfactorySatisfactorySatisfactory-24150
December 199177.5FairSatisfactorySatisfactorySatisfactory-26250

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.699699000
Reinforced Concrete Girder/Beamlinear ft.1,3181,3051300
Deck
Reinforced Concrete Decksq. ft.14,49814,498000
Substructure
Reinforced Concrete Columneach1616000
Reinforced Concrete Pier Walllinear ft.8484000
Reinforced Concrete Abutmentlinear ft.8884400
Reinforced Concrete Pileeach1515000
Reinforced Concrete Pier Caplinear ft.225225000
Joints
Strip Seal Jointlinear ft.4304300
Bearings
Elastomeric Bearingeach1616000
Movable Bearingeach1212000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.659659000