Share:

FAU 2869 over RAINES RD / SR-4

Map

Coordinates:
+35.03808, -89.91736
35°02'17" N, 89°55'02" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAU 2869 over RAINES RD / SR-4
Structure number:79SR0040005
Location:RAINES RD - MEMPHIS
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:128.0 ft. [39.0 m]
Total length:229.0 ft. [69.8 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:52.5 ft. [16.0 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1975
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:14,990 [as of 2017]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:82.3

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017FairSatisfactorySatisfactorySatisfactory1499082.3
March 2015FairSatisfactorySatisfactorySatisfactory1499080.3
March 2013FairSatisfactorySatisfactorySatisfactory1499080.3
April 2011FairSatisfactorySatisfactorySatisfactory1499080.3
May 2009FairSatisfactorySatisfactorySatisfactory1499080.3
August 2007FairSatisfactorySatisfactorySatisfactory1499080.3
September 2005FairFairFairSatisfactory1577067.8
September 2003PoorPoorPoorSatisfactory1584048.8
October 2001PoorPoorPoorSatisfactory1715048.5
February 2000PoorPoorSatisfactorySatisfactory1787075.8
June 1998PoorPoorSatisfactorySatisfactory1693079.0
November 1995FairGoodGoodSatisfactory1543092.8
August 1993FairGoodGoodSatisfactory1387092.9
November 1991FairGoodGoodSatisfactory1363092.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.23011012000
Deck
Reinforced Concrete Decksq. ft.12,0751,95510,12000
Wearing Surfacessq. ft.10,120010,12000
Substructure
Reinforced Concrete Columneach33000
Reinforced Concrete Abutmentlinear ft.105105000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.460460000