Share:

FAU 2869 over RAINES RD / SR-4

Map

Coordinates:
+35.03822, -89.91750
35°02'18" N, 89°55'03" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FAU 2869 over RAINES RD / SR-4
Structure number:79SR0040006
Location:RAINES RD - MEMPHIS
Purpose:Carries highway and pedestrian walkway over highway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:128.0 ft. [39.0 m]
Total length:229.0 ft. [69.8 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:40.4 ft. [12.3 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:1975
Historic significance:Historical significance is not determinable at this time [4]
Design load:MS 18 / HS 20 [5]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Box Beam or girders - Single or Spread [06]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:14,990 [as of 2017]
Truck traffic:5% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Satisfactory [6 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Underclearances appraisal:Equal to present desirable criteria [8]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:91.5

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
February 2017FairSatisfactorySatisfactorySatisfactory1499091.5
March 2015FairSatisfactorySatisfactorySatisfactory1499089.5
March 2013FairSatisfactorySatisfactorySatisfactory1499089.5
April 2011FairSatisfactorySatisfactorySatisfactory1499089.5
May 2009FairSatisfactorySatisfactorySatisfactory1499089.5
August 2007FairSatisfactorySatisfactorySatisfactory1499089.5
September 2005FairGoodSatisfactoryGood1577089.4
September 2003GoodGoodGoodGood1584089.4
October 2001GoodGoodGoodGood1715089.2
February 2000GoodGoodGoodGood1787089.1
June 1998GoodGoodGoodGood1693089.2
November 1995FairGoodGoodSatisfactory1543091.7
August 1993FairGoodGoodSatisfactory1387091.9
November 1991FairGoodGoodSatisfactory1363091.9

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Reinforced Concrete Girder/Beamlinear ft.23011012000
Deck
Reinforced Concrete Decksq. ft.9,0859,085000
Wearing Surfacessq. ft.7,4757,475000
Substructure
Reinforced Concrete Columneach22000
Reinforced Concrete Abutmentlinear ft.7979000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.4604303000