NFA A136 (SA 8714) over LITTLE CREEK

Map

Coordinates:
+36.21927, -83.71363
36°13'09" N, 83°42'49" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NFA A136 (SA 8714) over LITTLE CREEK
Structure number:870A1360003
Location:S OF SR131-2 M E OF LUTTR
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:12.5 ft. [3.8 m]
Total length:37.4 ft. [11.4 m]
Roadway width between curbs:22.0 ft. [6.7 m]
Deck width edge-to-edge:35.8 ft. [10.9 m]
Skew angle:30°
Owner:County Highway Agency [02]
Year built:1983
Historic significance:Historical significance is not determinable at this time [4]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:180 [as of 2019]
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Roadway alignment appraisal:Basically intolerable requiring high priority of corrrective action [3]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:71.8
Recommended work:Other structural work, including hydraulic replacements. [38]

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
August 2018Fair6 out of 1018071.8
August 2016Fair6 out of 1018071.8
September 2014Fair6 out of 1018073.8
September 2012Fair6 out of 1018084.0
October 2010Good7 out of 1018086.0
September 2008Good7 out of 1018086.0
September 2006Good7 out of 1018086.0
September 2004Good7 out of 1018084.0
July 2002Good7 out of 1018084.0
July 2000Good7 out of 1018083.9
September 1998Good7 out of 1018083.9
June 1996Good7 out of 1010097.0
September 1994Good7 out of 103097.0
June 1992Good7 out of 1010097.0
September 1990Good7 out of 1010097.0