Share:

NFA 2594 (SA 9033) over BRANCH

Map

Coordinates:
+36.42918, -82.63475
36°25'45" N, 82°38'05" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:NFA 2594 (SA 9033) over BRANCH
Structure number:90S23710001
Location:IN VERY NW CORNER OF CO.
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:15.1 ft. [4.6 m]
Total length:40.0 ft. [12.2 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:35.4 ft. [10.8 m]
Owner:County Highway Agency [02]
Year built:1933
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 13.5 / H 15 [2]
Number of main spans:2
Main spans material:Concrete continuous [2]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: June 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:1,110 [as of 2019]
Truck traffic:6% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:84.7

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
June 2018Good7 out of 10111084.7
June 2016Good7 out of 10111091.0
June 2014Good7 out of 10111091.0
June 2012Good7 out of 10111091.0
June 2010Good7 out of 10111091.0
June 2008Good7 out of 10111091.0
July 2006Good7 out of 10110091.0
September 2004Good7 out of 1098091.1
June 2002Good7 out of 10122091.0
June 2000Good8 out of 10117091.0
June 1998Good8 out of 10106091.1
August 1996Good8 out of 1092091.1
January 1994Good8 out of 1081091.2
July 1992Poor4 out of 1090048.1
September 1990Poor4 out of 1090060.9