Share:

FM 2127 over JONES CREEK

Map 

Coordinates:
+33.45700, -98.13317
33°27'25" N, 98°07'59" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FM 2127 over JONES CREEK
Structure number:021200128701002
Location:0.5 MI E OF POST OAK
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:6.9 ft. [2.1 m]
Total length:30.8 ft. [9.4 m]
Roadway width between curbs:28.5 ft. [8.7 m]
Deck width edge-to-edge:29.9 ft. [9.1 m]
Owner:State Highway Agency [01]
Year built:1955
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: January 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:140 [as of 2011]
Truck traffic:12% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:77.5

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
January 201577.5Fair6 out of 10FO140
January 201377.5Fair6 out of 10FO140
January 201197.5Fair6 out of 10-150
January 200997.5Good7 out of 10-160
January 200797.4Good7 out of 10-210
January 200597.4Good7 out of 10-190
January 200397.5Good7 out of 10-170
January 200197.3Good7 out of 10-250
January 199997.3Good7 out of 10-240
March 199797.4Good7 out of 10-210
February 199597.2Good7 out of 10-260
February 199393.4Good8 out of 10-220
February 199193.4Good8 out of 10-210