Share:

US 277 SB over BU 277

Map

Coordinates:
+33.61556, -99.24278
33°36'56" N, 99°14'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 277 SB over BU 277
Structure number:030120015615094
Location:4.03 MI N OF US 183/283
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:66.9 ft. [20.4 m]
Total length:201.1 ft. [61.3 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:40.0 ft. [12.2 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Owner:State Highway Agency [01]
Year built:2008
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: October 2017

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:2,600 [as of 2015]
Truck traffic:25% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Very Good [8 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Better than present minimum criteria [7]
Underclearances appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:98.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
October 2017GoodGoodVery GoodGood260098.0
October 2015GoodGoodVery GoodGood260098.0
October 2013GoodGoodVery GoodGood260098.0
November 2011GoodGoodVery GoodGood260098.0
October 2009GoodGoodVery GoodGood260098.0
December 2008GoodVery GoodVery GoodGood260098.0

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Prestressed Concrete Girder/Beamlinear ft.1,0051,005000
Deck
Reinforced Concrete Decksq. ft.8,0408,040000
Substructure
Reinforced Concrete Columneach66000
Reinforced Concrete Abutmentlinear ft.80562400
Reinforced Concrete Pier Caplinear ft.8080000
Bearings
Elastomeric Bearingeach3030000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.402401010