FM 281 over South Palo Duro Creek
Map
Coordinates:
+36.02332, -101.4523836°01'24" N, 101°27'09" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | FM 281 over South Palo Duro Creek |
Structure number: | 041180079406006 |
Location: | 5.0 Mi W of SH 136 |
Purpose: | Carries highway over waterway |
Route classification: | Major Collector (Rural) [07] |
Length of largest span: | 5.9 ft. [1.8 m] |
Total length: | 40.0 ft. [12.2 m] |
Roadway width between curbs: | 38.1 ft. [11.6 m] |
Deck width edge-to-edge: | 40.4 ft. [12.3 m] |
Owner: | State Highway Agency [01] |
Year built: | 1996 |
Historic significance: | Bridge is not eligible for the National Register of Historic Places [5] |
Number of main spans: | 6 |
Main spans material: | Steel [3] |
Main spans design: | Culvert [19] |
Deck type: | Corrugated Steel [6] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: August 2018
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 640 [as of 2013] |
Truck traffic: | 43% of total traffic |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5] |
Culvert condition: | Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 89.4 |
Previous Inspections
Date | Condition | Culvert Condition | ADT | Suff. Rating |
---|
August 2018 | Good | 7 out of 10 | 640 | 89.4 |
August 2016 | Good | 7 out of 10 | 640 | 89.1 |
August 2014 | Good | 7 out of 10 | 550 | 98.7 |
August 2012 | Good | 7 out of 10 | 550 | 98.7 |
January 2011 | Good | 7 out of 10 | 500 | 98.7 |
February 2009 | Good | 7 out of 10 | 490 | 98.8 |
February 2007 | Good | 7 out of 10 | 510 | 98.7 |
October 2005 | Good | 7 out of 10 | 510 | 99.7 |