US 87 SB over Big Blue Creek
Map
Coordinates:
+35.78309, -101.9577635°46'59" N, 101°57'28" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 87 SB over Big Blue Creek |
Structure number: | 041710006605026 |
Location: | 6.7 Mi N of SH 354 |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 29.9 ft. [9.1 m] |
Total length: | 213.9 ft. [65.2 m] |
Roadway width between curbs: | 37.1 ft. [11.3 m] |
Deck width edge-to-edge: | 40.0 ft. [12.2 m] |
Owner: | State Highway Agency [01] |
Year built: | 1933 |
Year reconstructed: | 1948 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | M 13.5 / H 15 [2] |
Number of main spans: | 7 |
Main spans material: | Concrete [1] |
Main spans design: | Tee beam [04] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: September 2017
Good/Fair/Poor Condition: | Fair |
Status: | Open, no restriction [A] |
Average daily traffic: | 5,320 [as of 2013] |
Truck traffic: | 3% of total traffic |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Fair [5 out of 9] |
Substructure condition: | Fair [5 out of 9] |
Structural appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Deck geometry appraisal: | Equal to present minimum criteria [6] |
Water adequacy appraisal: | Superior to present desirable criteria [9] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 73.4 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
September 2017 | Fair | Satisfactory | Fair | Fair | 5320 | 73.4 |
September 2015 | Fair | Satisfactory | Satisfactory | Satisfactory | 5320 | 86.4 |
September 2013 | Fair | Satisfactory | Satisfactory | Satisfactory | 4250 | 87.9 |
March 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 5000 | 86.9 |
March 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 4700 | 87.6 |
March 2008 | Fair | Satisfactory | Satisfactory | Satisfactory | 4200 | 88.3 |
March 2006 | Fair | Satisfactory | Satisfactory | Satisfactory | 4900 | 87.7 |
March 2004 | Fair | Satisfactory | Satisfactory | Satisfactory | 5000 | 87.3 |
June 2003 | Fair | Good | Good | Satisfactory | 4750 | 87.7 |
April 2002 | Fair | Good | Good | Satisfactory | 4400 | 89.1 |
May 2001 | Fair | Good | Good | Satisfactory | 4400 | 89.1 |
May 2000 | Fair | Good | Good | Satisfactory | 4000 | 89.6 |
June 1998 | Good | Good | Good | Good | 3950 | 88.7 |
June 1996 | Good | Good | Good | Good | 3950 | 88.7 |
June 1994 | Good | Good | Good | Good | 3700 | 67.3 |
June 1992 | Good | Good | Good | Good | 3300 | 68.0 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Superstructure |
Reinforced Concrete Girder/Beam | linear ft. | 1,708 | 1,492 | 155 | 61 | 0 |
Deck |
Reinforced Concrete Top Flange | sq. ft. | 8,540 | 8,515 | 23 | 2 | 0 |
Substructure |
Reinforced Concrete Abutment | linear ft. | 80 | 79 | 1 | 0 | 0 |
Reinforced Concrete Pile | each | 48 | 28 | 12 | 8 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 228 | 104 | 111 | 13 | 0 |
Bridge Rail |