Share:

FM 765 over DRAW

Map

Coordinates:
+31.38672, -99.88434
31°23'12" N, 99°53'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 765 over DRAW
Structure number:070480087004028
Location:0.20 MI W OF US 83
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:7.9 ft. [2.4 m]
Total length:51.8 ft. [15.8 m]
Roadway width between curbs:44.0 ft. [13.4 m]
Deck width edge-to-edge:45.3 ft. [13.8 m]
Owner:State Highway Agency [01]
Year built:1969
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2014

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:290 [as of 2011]
Truck traffic:5% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:96.6

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 201496.6Good7 out of 10-290
July 201096.7Good7 out of 10-210
August 200696.7Good7 out of 10-280
August 200296.6Good7 out of 10-320
September 199896.7Good7 out of 10-270
August 199696.6Good7 out of 10-280
September 199496.6Good7 out of 10-330
July 199093.7Good7 out of 10-250