Share:

FM 2134 over WEST MUSTANG CREEK

Map

Coordinates:
+31.40622, -99.75565
31°24'22" N, 99°45'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 2134 over WEST MUSTANG CREEK
Structure number:070480200603011
Location:0.15 MI S OF FM 765
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:9.8 ft. [3.0 m]
Total length:76.1 ft. [23.2 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:29.2 ft. [8.9 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1969
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2014

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:110 [as of 2011]
Truck traffic:4% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:97.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
July 201497.0Good7 out of 10-110
July 201097.0Good7 out of 10-130
August 200697.0Good7 out of 10-150
August 200297.0Good7 out of 10-180
September 199897.0Good7 out of 10-160
August 199697.0Good7 out of 10-140
September 199497.0Good7 out of 10-160
July 199094.1Good7 out of 10-120