CR 138 over DUCK CREEK
Map
Coordinates:
+33.38849, -100.7520933°23'19" N, 100°45'08" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | CR 138 over DUCK CREEK |
Structure number: | 081320AA0154001 |
Location: | 1.15 MI N OF CR 179 |
Purpose: | Carries highway over waterway |
Route classification: | Local (Rural) [09] |
Length of largest span: | 48.9 ft. [14.9 m] |
Total length: | 49.9 ft. [15.2 m] |
Roadway width between curbs: | 19.4 ft. [5.9 m] |
Deck width edge-to-edge: | 20.0 ft. [6.1 m] |
Owner: | County Highway Agency [02] |
Year built: | 1955 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Main span material: | Steel [3] |
Main span design: | Stringer/Multi-beam or girder [02] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Monolithic Concrete (concurrently placed with structural deck) [1] |
Latest Available Inspection: February 2016
Good/Fair/Poor Condition: | Fair |
Status: | Posted for load [P] |
Average daily traffic: | 55 [as of 2010] |
Deck condition: | Satisfactory [6 out of 9] |
Superstructure condition: | Satisfactory [6 out of 9] |
Substructure condition: | Satisfactory [6 out of 9] |
Structural appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Deck geometry appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Water adequacy appraisal: | Meets minimum tolerable limits to be left in place as is [4] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6] |
Scour condition: | Bridge foundations determined to be stable for assessed or calculated scour condition. [5] |
Sufficiency rating: | 62.3 |
Recommended work: | Other structural work, including hydraulic replacements. [38] |
Estimated cost of work: | $83,000 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
February 2016 | Fair | Satisfactory | Satisfactory | Satisfactory | 55 | 62.3 |
February 2014 | Fair | Satisfactory | Satisfactory | Satisfactory | 55 | 62.3 |
February 2012 | Fair | Satisfactory | Satisfactory | Satisfactory | 55 | 62.3 |
February 2010 | Fair | Satisfactory | Satisfactory | Satisfactory | 55 | 62.5 |
February 2008 | Fair | Good | Satisfactory | Good | 55 | 58.5 |
February 2006 | Fair | Good | Satisfactory | Good | 55 | 58.5 |
February 2004 | Fair | Good | Satisfactory | Good | 55 | 59.3 |
April 2002 | Fair | Good | Satisfactory | Good | 55 | 59.3 |
May 2000 | Good | Good | Good | Good | 55 | 59.3 |
July 1998 | Fair | Good | Satisfactory | Good | 55 | 59.3 |
May 1996 | Fair | Very Good | Satisfactory | Good | 55 | 62.3 |
July 1994 | Fair | Satisfactory | Satisfactory | Good | 55 | 60.3 |
December 1991 | Fair | Satisfactory | Satisfactory | Good | 55 | 63.4 |