Share:

FM 1308 over HUNTING CREEK

Map

Coordinates:
+32.39514, -101.06176
32°23'43" N, 101°03'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 1308 over HUNTING CREEK
Structure number:081680051801005
Location:1.6 MI W OF FM 670
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:24.9 ft. [7.6 m]
Total length:75.1 ft. [22.9 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:21.3 ft. [6.5 m]
Owner:State Highway Agency [01]
Year built:1938
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 9 / H 10 [1]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Slab [01]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2015

Good/Fair/Poor Condition:Fair
Status:Posted for load [P]
Average daily traffic:130 [as of 2013]
Truck traffic:39% of total traffic
Deck condition:Good [7 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Satisfactory [6 out of 9]
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:34.7 tons [31.5 metric tons]
Inventory rating:16.8 tons [15.3 metric tons]
Sufficiency rating:56.5

Previous Inspections

DateSuff. RatingConditionDeckSuperstructureSubstructureSD/FOADT
March 201556.5FairGoodGoodSatisfactory-130
May 201356.5FairGoodGoodSatisfactory-110
May 201171.0FairVery GoodGoodSatisfactory-90
May 200971.2FairGoodGoodSatisfactory-90
April 200756.7FairGoodGoodSatisfactory-140
April 200570.3FairGoodGoodSatisfactory-120
April 200384.5FairGoodGoodSatisfactory-50
April 200184.5FairVery GoodGoodSatisfactory-50
March 199979.5FairGoodGoodSatisfactory-70
May 199779.5GoodGoodGoodGood-80
May 199577.5FairGoodGoodSatisfactory-70
March 199362.2FairSatisfactoryGoodGood-150
August 199062.2FairGoodGoodSatisfactory-150

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Substructure
Steel Columneach60060
Steel Protective Coatingsq. ft.1,9981,998000
Reinforced Concrete Abutmentlinear ft.1211100
Reinforced Concrete Pier Caplinear ft.1211100
Joints
Pourable Jointlinear ft.1212000
Deck
Reinforced Concrete Slabsq. ft.33000