Share:

FM 1899 over LONE WOLF DRAW

Map

Coordinates:
+32.40433, -100.80768
32°24'16" N, 100°48'28" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 1899 over LONE WOLF DRAW
Structure number:081680247201001
Location:0.4 MI N OF IH 20
Purpose:Carries highway over waterway
Route classification:Minor Collector (Rural) [08]
Length of largest span:5.9 ft. [1.8 m]
Total length:23.0 ft. [7.0 m]
Roadway width between curbs:32.2 ft. [9.8 m]
Deck width edge-to-edge:35.1 ft. [10.7 m]
Skew angle:30°
Owner:State Highway Agency [01]
Year built:1963
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:150 [as of 2013]
Truck traffic:15% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:96.9

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
May 201596.9Fair6 out of 10-150
May 201196.9Fair6 out of 10-170
May 200996.9Fair6 out of 10-150
April 200787.0Fair6 out of 10-200
April 200587.0Fair6 out of 10-220
March 200386.7Good7 out of 10-150
April 200186.8Good7 out of 10-120
March 199984.7Good7 out of 10-140
May 199784.7Good7 out of 10-140
May 199591.9Fair6 out of 10-180
March 199392.0Good7 out of 10-130
August 199092.0Good7 out of 10-140

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Culvert
Reinforced Concrete Culvertlinear ft.3734300