Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR 409 over STINKING CREEK
Structure number:082170AA0184001
Location:4.1 MI N OF FM 2211
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:7.9 ft. [2.4 m]
Total length:60.0 ft. [18.3 m]
Roadway width between curbs:23.6 ft. [7.2 m]
Deck width edge-to-edge:25.9 ft. [7.9 m]
Owner:County Highway Agency [02]
Year built:1997
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:7
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:50 [as of 2014]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:97.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
February 2016Good7 out of 105097.0
February 2014Good7 out of 105098.0
February 2012Good7 out of 105098.0
February 2010Good7 out of 105098.0
February 2008Good7 out of 105098.0
January 2006Good7 out of 105098.0
February 2004Good7 out of 105099.0
April 2002Good7 out of 1050100.0
May 2000Good8 out of 105098.0
April 1998Good8 out of 105098.0
May 1997Good8 out of 1050100.0
May 1996PoorN out of 105024.9
May 1995PoorN out of 105023.0
August 1994PoorN out of 105023.0
December 1991PoorN out of 105023.0