Share:

CR 411 over STINKING CREEK

Map

Coordinates:
+33.17954, -100.32084
33°10'46" N, 100°19'15" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:CR 411 over STINKING CREEK
Structure number:082170AA0189001
Location:0.04 MI W OF CR 409
Purpose:Carries highway over waterway
Route classification:Local (Rural) [09]
Length of largest span:7.9 ft. [2.4 m]
Total length:52.2 ft. [15.9 m]
Roadway width between curbs:23.6 ft. [7.2 m]
Deck width edge-to-edge:25.9 ft. [7.9 m]
Owner:County Highway Agency [02]
Year built:2003
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:100 [as of 2014]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present minimum criteria [6]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.0

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
February 2016Good7 out of 1010098.0
February 2014Good7 out of 1010099.0
February 2012Good7 out of 1010099.0
February 2010Good7 out of 1010099.0
February 2008Good7 out of 105099.0
January 2006Good7 out of 105099.0
February 2004Good7 out of 105099.0
April 2002-N out of 105019.5
May 2000-N out of 105036.3
April 1998FairN out of 105025.3
May 1996FairN out of 105029.5
July 1994PoorN out of 105019.5
December 1991FairN out of 105026.8