Share:

FM 1254 over EDMOORE CREEK

Map

Coordinates:
+32.74353, -95.41773
32°44'37" N, 95°25'04" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 1254 over EDMOORE CREEK
Structure number:102500139003006
Location:1.15 MI W OF FM 778
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:4.9 ft. [1.5 m]
Total length:23.0 ft. [7.0 m]
Roadway width between curbs:30.8 ft. [9.4 m]
Deck width edge-to-edge:33.8 ft. [10.3 m]
Owner:State Highway Agency [01]
Year built:1951
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:330 [as of 2013]
Truck traffic:17% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Equal to present minimum criteria [6]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Better than present minimum criteria [7]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Moderate to major deterioration or disintegration, extensive cracking and leaching or spalls on concrete or masonry walls and slabs. Minor settlement or misalignment. Noticeable scouring or erosion at curtain walls, wingwalls or pipes. Metal culverts have significant distortion and deflection in one section, significant corrosion or deep pitting. [5]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Sufficiency rating:81.3
Recommended work:Other structural work, including hydraulic replacements. [38]
Estimated cost of work:$60,000

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
September 2016Fair5 out of 1033081.3
September 2014Fair5 out of 1030081.4
September 2012Fair5 out of 1030078.9
September 2010Fair6 out of 1027089.9
September 2008Fair6 out of 1027089.9
September 2006Fair5 out of 1031075.9
October 2004Fair5 out of 1037075.8
November 2002Poor4 out of 1030059.8
March 2001Poor4 out of 1030049.8
February 1999Poor4 out of 1023054.3
April 1997Poor4 out of 1023059.8
January 1995Poor4 out of 1026067.0
December 1992Poor4 out of 1018067.0
December 1988Good7 out of 1018094.1