Share:

US 77 SB over FM 1898

Map

Coordinates:
+27.53114, -97.84019
27°31'52" N, 97°50'25" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 77 SB over FM 1898
Structure number:161370010204123
Location:0.55 MI N OF FM 2045
Purpose:Carries highway over highway
Route classification:Principal Arterial - Other Freeways or Expressways (Urban) [12]
Length of largest span:122.1 ft. [37.2 m]
Total length:319.9 ft. [97.5 m]
Roadway width between curbs:38.1 ft. [11.6 m]
Deck width edge-to-edge:40.0 ft. [12.2 m]
Vertical clearance below bridge:16.4 ft. [5.0 m]
Skew angle:20°
Owner:State Highway Agency [01]
Year built:2005
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Number of main spans:3
Main spans material:Prestressed concrete [5]
Main spans design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Precast Panels [2]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: July 2016

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:10,200 [as of 2013]
Truck traffic:16% of total traffic
Deck condition:Satisfactory [6 out of 9]
Superstructure condition:Good [7 out of 9]
Substructure condition:Good [7 out of 9]
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Equal to present minimum criteria [6]
Underclearances appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Scour condition:Bridge not over waterway. [N]
Sufficiency rating:100.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
July 2016FairSatisfactoryGoodGood10200100.0
July 2014FairSatisfactoryGoodGood975098.0
August 2012FairSatisfactoryGoodGood975098.0
July 2010FairSatisfactoryVery GoodGood977098.0
July 2008GoodGoodVery GoodGood970098.0
May 2006GoodVery GoodVery GoodGood850098.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Substructure
Reinforced Concrete Abutmentlinear ft.82041410
Reinforced Concrete Pier Caplinear ft.8080000
Joints
Strip Seal Jointlinear ft.8484000
Bearings
Elastomeric Bearingeach3232000
Bridge Rail
Reinforced Concrete Bridge Raillinear ft.664656800