Share:

SH 36 over THOMPSON CREEK

Map

Coordinates:
+30.35032, -96.53262
30°21'01" N, 96°31'57" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SH 36 over THOMPSON CREEK
Structure number:170260018603040
Location:0.3 MI N OF FM 1361
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:7.9 ft. [2.4 m]
Total length:25.9 ft. [7.9 m]
Roadway width between curbs:65.9 ft. [20.1 m]
Deck width edge-to-edge:95.8 ft. [29.2 m]
Owner:State Highway Agency [01]
Year built:1937
Year reconstructed:2000
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2018

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:9,960 [as of 2013]
Truck traffic:22% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:71.1

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
August 2018Good7 out of 10996071.1
August 2016Good7 out of 10996070.9
August 2014Fair6 out of 101000070.9
September 2012Fair6 out of 101000070.9
September 2010Fair6 out of 10860071.2
September 2008Good7 out of 10960071.1
September 2006Good7 out of 10992071.1
September 2004Good7 out of 101080070.8
October 2002Good7 out of 10830071.1
October 2000Good7 out of 10920072.0
January 1999Good7 out of 101000071.9
April 1997Good7 out of 10840072.1
April 1995Good7 out of 10840079.8
April 1993Good7 out of 10800079.9
October 1989Good8 out of 10790079.9

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.28815113700