Share:

IH 45 EFR over CANE BRANCH

Map

Coordinates:
+31.45331, -96.07833
31°27'12" N, 96°04'42" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IH 45 EFR over CANE BRANCH
Structure number:171450067503140
Location:0.2 MI N OF US 79
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:8.9 ft. [2.7 m]
Total length:60.0 ft. [18.3 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:27.2 ft. [8.3 m]
Skew angle:15°
Owner:State Highway Agency [01]
Year built:1969
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:380 [as of 2013]
Truck traffic:28% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Better than present minimum criteria [7]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:91.4

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
March 201591.4Fair6 out of 10-380
March 201391.4Fair6 out of 10-370
March 201191.4Fair6 out of 10-390
March 200996.8Fair6 out of 10-690
March 200796.4Fair6 out of 10-2710
March 200596.3Fair6 out of 10-2880
April 200396.5Fair6 out of 10-2200
April 200175.3Fair6 out of 10FO2154
December 199894.9Good7 out of 10-510
February 199794.9Good7 out of 10-9000
March 199597.0Good7 out of 10-170
June 199397.0Good7 out of 10-130
August 198996.9Good8 out of 10-240

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Culvert
Reinforced Concrete Culvertlinear ft.5145600