Share:

IH 45 WFR over DRAIN

Map

Coordinates:
+31.43118, -96.05962
31°25'52" N, 96°03'35" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:IH 45 WFR over DRAIN
Structure number:171450067503146
Location:1.65 MI S OF US 79
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:6.9 ft. [2.1 m]
Total length:38.1 ft. [11.6 m]
Roadway width between curbs:20.0 ft. [6.1 m]
Deck width edge-to-edge:43.0 ft. [13.1 m]
Owner:State Highway Agency [01]
Year built:1969
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:570 [as of 2013]
Truck traffic:27% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Basically intolerable requiring high priority of corrrective action [3]
Water adequacy appraisal:Meets minimum tolerable limits to be left in place as is [4]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:75.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
March 201575.0Good7 out of 10FO570
March 201377.4Good7 out of 10-330
March 201177.3Good7 out of 10-370
March 200994.3Good7 out of 10-510
March 200786.7Good7 out of 10-2570
March 200578.5Good7 out of 10-2740
April 200387.3Good7 out of 10-2150
April 200171.7Good7 out of 10FO2354
December 199894.5Good7 out of 10-380
February 199782.0Good7 out of 10-19350
March 199596.8Good7 out of 10-170
March 199396.8Good7 out of 10-160
August 198996.7Good8 out of 10-230

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Culvert
Reinforced Concrete Culvertlinear ft.6562300