Share:

SH 289 over DRAIN

Map

Coordinates:
+33.09045, -96.80549
33°05'26" N, 96°48'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SH 289 over DRAIN
Structure number:180430009105061
Location:0.4 MI. S. OF SH 121
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:7.9 ft. [2.4 m]
Total length:34.1 ft. [10.4 m]
Roadway width between curbs:96.1 ft. [29.3 m]
Deck width edge-to-edge:133.9 ft. [40.8 m]
Owner:State Highway Agency [01]
Year built:1993
Year reconstructed:2001
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: January 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:26,850 [as of 2013]
Truck traffic:5% of total traffic
Structural appraisal:Better than present minimum criteria [7]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Superior to present desirable criteria [9]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:87.3

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
January 2016Good7 out of 102685087.3
March 2012Good7 out of 104400085.3
March 2010Good7 out of 104400085.3
February 2008Good7 out of 104400085.3
March 2006Good7 out of 104200085.9
January 2006Good7 out of 104200085.7
March 2002Good7 out of 103500087.6
January 2000Good7 out of 101820074.3
March 1998Good7 out of 101600075.6
March 1996Good7 out of 101600074.6
March 1994Good7 out of 101460091.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.5365162000