Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 281 SB FR over PALO BLANCO CREEK
Structure number:210240025503112
Location:0.15 MI N OF SH 285
Purpose:Carries highway over waterway
Route classification:Other Principal Arterial (Urban) [14]
Length of largest span:6.9 ft. [2.1 m]
Total length:53.2 ft. [16.2 m]
Roadway width between curbs:38.7 ft. [11.8 m]
Deck width edge-to-edge:56.4 ft. [17.2 m]
Skew angle:
Owner:State Highway Agency [01]
Year built:2000
Year reconstructed:2013
Historic significance:Bridge is not eligible for the National Register of Historic Places [5]
Design load:MS 18 / HS 20 [5]
Number of main spans:6
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: May 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:11,400 [as of 2010]
Truck traffic:5% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:98.9

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
May 2017Fair6 out of 101140098.9
June 2014Fair6 out of 101140098.9
February 2013Fair6 out of 101140095.9
May 2009Fair6 out of 101140098.9
May 2007Fair6 out of 101140098.9
May 2005Fair6 out of 101140098.9
May 2003Fair6 out of 101140083.7
June 2001Good7 out of 1024085.0
November 2000Good7 out of 1024085.0

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.3392994000