Name:FM 754 over CIBOLO CREEK
Structure number:210240069602007
Location:0.20 MI S OF FM 1418
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:9.8 ft. [3.0 m]
Total length:52.2 ft. [15.9 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:28.2 ft. [8.6 m]
Owner:State Highway Agency [01]
Year built:1971
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Monolithic Concrete (concurrently placed with structural deck) [1]

Latest Available Inspection: February 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:300 [as of 2013]
Truck traffic:35% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:92.4

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
February 2017Fair6 out of 1030092.4
February 2013Fair6 out of 1026092.4
May 2009Fair6 out of 1021096.9
May 2005Fair6 out of 1030091.4
June 2001Fair6 out of 1030094.4
August 1997Fair6 out of 1039094.4
August 1995Good7 out of 1029093.9
March 1993Good8 out of 1028093.9