US 77 SB over DRAIN & STOCK PASS
Map
Coordinates:
+27.19632, -97.7914627°11'47" N, 97°47'29" W
Facts
Source: National Bridge Inventory. Information not verified; use at your own risk.
Name: | US 77 SB over DRAIN & STOCK PASS |
Structure number: | 210660032702019 |
Location: | 5.40 MI S OF KLEBERG C/L |
Purpose: | Carries highway over waterway |
Route classification: | Principal Arterial - Other (Rural) [02] |
Length of largest span: | 29.9 ft. [9.1 m] |
Total length: | 80.1 ft. [24.4 m] |
Roadway width between curbs: | 39.7 ft. [12.1 m] |
Deck width edge-to-edge: | 42.0 ft. [12.8 m] |
Owner: | State Highway Agency [01] |
Year built: | 1952 |
Historic significance: | Bridge is possibly eligible for the National Register of Historic Places [3] |
Design load: | MS 18 / HS 20 [5] |
Number of main spans: | 3 |
Main spans material: | Concrete continuous [2] |
Main spans design: | Slab [01] |
Deck type: | Concrete Cast-in-Place [1] |
Wearing surface: | Bituminous [6] |
Latest Available Inspection: February 2017
Good/Fair/Poor Condition: | Good |
Status: | Open, no restriction [A] |
Average daily traffic: | 4,390 [as of 2013] |
Truck traffic: | 26% of total traffic |
Deck condition: | Very Good [8 out of 9] |
Superstructure condition: | Very Good [8 out of 9] |
Substructure condition: | Good [7 out of 9] |
Structural appraisal: | Equal to present minimum criteria [6] |
Deck geometry appraisal: | Better than present minimum criteria [7] |
Water adequacy appraisal: | Somewhat better than minimum adequacy to tolerate being left in place as is [5] |
Roadway alignment appraisal: | Equal to present desirable criteria [8] |
Channel protection: | Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7] |
Scour condition: | Bridge foundations determined to be stable for the assessed or calculated scour condition. [8] |
Sufficiency rating: | 93.7 |
Previous Inspections
Date | Condition | Deck | Superstructure | Substructure | ADT | Suff. Rating |
---|
February 2017 | Good | Very Good | Very Good | Good | 4390 | 93.7 |
February 2015 | Good | Good | Good | Good | 4390 | 94.4 |
February 2013 | Good | Good | Good | Good | 4900 | 96.5 |
April 2011 | Good | Good | Good | Good | 5000 | 96.5 |
May 2009 | Good | Good | Good | Good | 5050 | 96.5 |
May 2007 | Good | Good | Good | Good | 4500 | 96.6 |
May 2005 | Good | Good | Good | Good | 4750 | 96.6 |
May 2003 | Good | Good | Good | Good | 5200 | 97.5 |
June 2001 | Good | Very Good | Good | Good | 4550 | 97.6 |
June 1999 | Good | Very Good | Good | Good | 4750 | 97.6 |
September 1997 | Good | Good | Good | Good | 3700 | 97.7 |
September 1995 | Good | Very Good | Very Good | Good | 3550 | 97.7 |
April 1993 | Good | Very Good | Good | Good | 3400 | 97.7 |
January 1991 | Good | Very Good | Good | Good | 3150 | 97.8 |
Element Data
Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
Element | Units | Quantity | 1-Good | 2-Fair | 3-Poor | 4-Serious |
---|
Substructure |
Reinforced Concrete Abutment | linear ft. | 84 | 84 | 0 | 0 | 0 |
Reinforced Concrete Pier Cap | linear ft. | 84 | 79 | 3 | 2 | 0 |
Bridge Rail |
Reinforced Concrete Bridge Rail | linear ft. | 160 | 160 | 0 | 0 | 0 |
Deck |
Reinforced Concrete Slab | sq. ft. | 33 | 33 | 0 | 0 | 0 |