Share:

US 90 over DRAW

Map

Coordinates:
+29.24029, -100.17218
29°14'25" N, 100°10'20" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:US 90 over DRAW
Structure number:221360002304023
Location:3.90 MI W OF UVALDE C/L
Purpose:Carries highway over waterway
Route classification:Principal Arterial - Other (Rural) [02]
Length of largest span:5.9 ft. [1.8 m]
Total length:73.2 ft. [22.3 m]
Roadway width between curbs:56.1 ft. [17.1 m]
Deck width edge-to-edge:57.4 ft. [17.5 m]
Owner:State Highway Agency [01]
Year built:1932
Year reconstructed:1957
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Number of main spans:11
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: September 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:2,760 [as of 2013]
Truck traffic:14% of total traffic
Structural appraisal:Meets minimum tolerable limits to be left in place as is [4]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:73.1

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
September 2016Good7 out of 10276073.1
September 2014Fair6 out of 10310073.1
September 2012Fair6 out of 10310070.4
October 2010Fair6 out of 10310065.5
October 2008Fair6 out of 10360073.3
November 2006Fair6 out of 10320095.0
November 2004Fair6 out of 10290095.0
February 2001Fair6 out of 10310095.0
February 1999Good7 out of 10270095.0
October 1996Good7 out of 10240096.0
August 1994Good7 out of 10280095.0
April 1990Good7 out of 10260091.1

Element Data

Source: National Bridge Elements dataset, 2018 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Culvert
Reinforced Concrete Culvertlinear ft.63058830120