Share:

SPUR 406 over CALIFORNIA CREEK

Map

Coordinates:
+29.57656, -101.04432
29°34'36" N, 101°02'40" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SPUR 406 over CALIFORNIA CREEK
Structure number:222330002215046
Location:2.20 MI SE OF US 90
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:6.9 ft. [2.1 m]
Total length:22.0 ft. [6.7 m]
Roadway width between curbs:33.8 ft. [10.3 m]
Deck width edge-to-edge:37.1 ft. [11.3 m]
Owner:State Highway Agency [01]
Year built:1938
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: October 2016

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:40 [as of 2013]
Truck traffic:11% of total traffic
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Banks are protected or well vegetated. River control devices such as spur dikes and embankment protection are not required or are in a stable condition. [8]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Sufficiency rating:73.7

Previous Inspections

DateConditionCulvert ConditionADTSuff. Rating
October 2016Good7 out of 104073.7
December 2014Good7 out of 106073.4
December 2012Good7 out of 106073.4
February 2011Good7 out of 108073.2
February 2010Fair6 out of 106079.3
January 2008Fair6 out of 1050100.0
March 2005Good7 out of 105097.0
January 2001Good7 out of 109097.0
February 1999Good7 out of 108097.0
October 1996Good7 out of 107097.0
September 1994Good7 out of 1011097.0
May 1990Good8 out of 108094.1