US 62 over DRAW


+34.41194, -100.23455
34°24'43" N, 100°14'04" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.


Name:US 62 over DRAW
Structure number:250380003201001
Location:1.65MI S OF US 287
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:9.8 ft. [3.0 m]
Total length:33.1 ft. [10.1 m]
Roadway width between curbs:44.9 ft. [13.7 m]
Deck width edge-to-edge:109.3 ft. [33.3 m]
Owner:State Highway Agency [01]
Year built:1930
Year reconstructed:2001
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 18 / H 20 [4]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,660 [as of 2013]
Truck traffic:12% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank is beginning to slump. River control devices and embankment protection have widespread minor damage. There is minor stream bed movement evident. Debris is restricting the channel slightly. [6]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:96.0

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
August 201596.0Fair6 out of 10-2660
August 201397.5Fair6 out of 10-1650
August 201197.4Fair6 out of 10-1750
August 200997.2Fair6 out of 10-1850
September 200795.2Fair6 out of 10-1830
September 200595.1Fair6 out of 10-1950
September 200392.0Fair6 out of 10-2000
October 200191.8Fair6 out of 10-2100
September 199992.4Fair6 out of 10-1750
April 199892.7Good7 out of 10-1550
March 199695.7Good7 out of 10-1550
May 199495.1Good7 out of 10-1900
March 199292.3Good8 out of 10-1800
May 198893.0Good8 out of 10-1350