Share:

FM 268 over DRAW

Map 

Coordinates:
+34.43513, -100.02398
34°26'06" N, 100°01'26" W
Source: National Bridge Inventory
Information not verified. Use at your own risk.

Facts 

Name:FM 268 over DRAW
Structure number:250380253302004
Location:1.751MI E JCT FM 1033
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:9.8 ft. [3.0 m]
Total length:33.1 ft. [10.1 m]
Roadway width between curbs:21.0 ft. [6.4 m]
Deck width edge-to-edge:31.2 ft. [9.5 m]
Owner:State Highway Agency [01]
Year built:1962
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:3
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: August 2015 

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:50 [as of 2013]
Truck traffic:20% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:96.0

Previous Inspections 

DateSuff. RatingConditionCulvert ConditionSD/FOADT
August 201596.0Fair6 out of 10-50
August 201396.0Fair6 out of 10-80
August 201196.0Fair6 out of 10-60
August 200996.0Fair6 out of 10-40
August 200797.0Fair6 out of 10-70
September 200597.0Fair6 out of 10-90
October 200396.0Fair6 out of 10-90
October 200196.0Fair6 out of 10-90
October 199996.0Good7 out of 10-70
April 199897.0Good7 out of 10-80
April 1996100.0Good8 out of 10-80
May 199499.9Good8 out of 10-210
March 199297.1Good8 out of 10-60
May 198897.0Good8 out of 10-70