Share:

FM 1056 over DRAW

Map

Coordinates:
+34.84909, -100.34584
34°50'57" N, 100°20'45" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 1056 over DRAW
Structure number:250440177201002
Location:3.99 MI E OF FM 1547
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:5.9 ft. [1.8 m]
Total length:26.9 ft. [8.2 m]
Roadway width between curbs:25.9 ft. [7.9 m]
Deck width edge-to-edge:27.2 ft. [8.3 m]
Owner:State Highway Agency [01]
Year built:1953
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:MS 18 / HS 20 [5]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: July 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:990 [as of 2013]
Truck traffic:8% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:84.5

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
July 201584.5Fair6 out of 10-990
July 201396.0Fair6 out of 10-140
July 201196.0Fair6 out of 10-170
July 200996.0Fair6 out of 10-200
July 200796.9Fair6 out of 10-250
August 200596.9Fair6 out of 10-250
August 200396.9Fair6 out of 10-270
August 200196.9Fair6 out of 10-250
September 199996.9Fair6 out of 10-220
October 199796.9Fair6 out of 10-260
November 199599.9Good7 out of 10-260
February 199499.9Fair6 out of 10-320
January 199297.0Fair6 out of 10-270

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Culvert
Reinforced Concrete Culvertlinear ft.33181230