Share:

FM 104 over DRAW

Map

Coordinates:
+34.28847, -99.92622
34°17'19" N, 99°55'34" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:FM 104 over DRAW
Structure number:251000071101017
Location:2.57 MI W OF FM 2363
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:4.9 ft. [1.5 m]
Total length:22.0 ft. [6.7 m]
Roadway width between curbs:40.7 ft. [12.4 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Owner:State Highway Agency [01]
Year built:1947
Year reconstructed:1958
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Number of main spans:4
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Good
Status:Open, no restriction [A]
Average daily traffic:180 [as of 2013]
Truck traffic:29% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Shrinkage cracks, light scaling and insignificant spalling which does not expose reinforcing steel. Insignificant damage caused by drift with no misalignment and not requiring corrective action. Some minor scouring has occured near curtain walls, wingwalls or pipes. Metal culverts have a smooth symmetrical curvature with superficial corrosion and no pitting. [7]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:89.5

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 201589.5Good7 out of 10-180
June 201389.5Good7 out of 10-160
June 201189.5Good7 out of 10-90
August 200989.8Good7 out of 10-160
September 200789.8Good7 out of 10-200
September 200589.8Good7 out of 10-130
September 200389.5Good7 out of 10-180
January 200289.5Good7 out of 10-190
November 199974.0Good7 out of 10-140
April 199889.5Good7 out of 10-170
February 199692.5Good7 out of 10-170
May 199492.5Good7 out of 10-280
May 199286.6Good8 out of 10-170
May 198886.6Good8 out of 10-150

Element Data

Source: National Bridge Elements dataset, 2016 edition. This feature is experimental.
ElementUnitsQuantity1. Good2. Fair3. Poor4. Serious
Culvert
Reinforced Concrete Culvertlinear ft.5149200