Facts

Name:FM 104 over DRAW
Structure number:251000071101018
Location:2.98 MI E OF COTTLE C/L
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:5.9 ft. [1.8 m]
Total length:33.1 ft. [10.1 m]
Roadway width between curbs:40.7 ft. [12.4 m]
Deck width edge-to-edge:42.0 ft. [12.8 m]
Owner:State Highway Agency [01]
Year built:1947
Year reconstructed:1958
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 13.5 / H 15 [2]
Number of main spans:5
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:150 [as of 2013]
Truck traffic:29% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Superior to present desirable criteria [9]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:35.6 tons [32.4 metric tons]
Inventory rating:26.7 tons [24.3 metric tons]
Sufficiency rating:89.5

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 201589.5Fair6 out of 10-150
June 201389.5Fair6 out of 10-110
June 201189.5Fair6 out of 10-70
August 200989.8Fair6 out of 10-120
September 200789.8Fair6 out of 10-160
September 200589.8Fair6 out of 10-120
September 200389.5Fair6 out of 10-140
January 200289.5Fair6 out of 10-150
November 199984.0Good7 out of 10-110
April 199889.5Good7 out of 10-170
February 199692.5Good8 out of 10-170
May 199492.5Good8 out of 10-230
May 199286.6Good8 out of 10-130
May 198886.6Good8 out of 10-120