Facts

Name:FM 1167 over DRAW
Structure number:251000083203006
Location:3.02 MI W OF FM 392
Purpose:Carries highway over waterway
Route classification:Major Collector (Rural) [07]
Length of largest span:6.9 ft. [2.1 m]
Total length:21.0 ft. [6.4 m]
Roadway width between curbs:34.1 ft. [10.4 m]
Deck width edge-to-edge:35.4 ft. [10.8 m]
Skew angle:45°
Owner:State Highway Agency [01]
Year built:1966
Historic significance:Bridge is possibly eligible for the National Register of Historic Places [3]
Design load:M 18 / H 20 [4]
Number of main spans:2
Main spans material:Concrete [1]
Main spans design:Culvert [19]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: June 2015

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:120 [as of 2013]
Truck traffic:15% of total traffic
Structural appraisal:Equal to present minimum criteria [6]
Deck geometry appraisal:Better than present minimum criteria [7]
Water adequacy appraisal:Equal to present minimum criteria [6]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is in need of minor repairs. River control devices and embankment protection have a little minor damage. Banks and/or channel have minor amounts of drift. [7]
Culvert condition:Deterioration or initial disintegration, minor chloride contamination, cracking with some leaching, or spalls on concrete or masonry walls and slabs. Local minor scouring at curtain walls, wingwalls or pipes. Metal culverts have a smooth curvature, non-symmetrical shape, significant corrosion or moderate pitting. [6]
Scour condition:Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Operating rating:48.5 tons [44.1 metric tons]
Inventory rating:35.6 tons [32.4 metric tons]
Sufficiency rating:97.0

Previous Inspections

DateSuff. RatingConditionCulvert ConditionSD/FOADT
June 201597.0Fair6 out of 10-120
June 201397.0Fair6 out of 10-200
June 201197.0Fair6 out of 10-200
August 200997.0Fair6 out of 10-190
September 200797.0Fair6 out of 10-200
September 200597.0Fair6 out of 10-200
September 200397.0Fair6 out of 10-130
January 200297.0Fair6 out of 10-180
November 199981.5Fair6 out of 10-130
May 199897.0Fair6 out of 10-190
March 1996100.0Fair6 out of 10-190
May 1994100.0Good7 out of 10-100
May 199297.1Good7 out of 10-140
May 198897.1Good7 out of 10-190