Share:

SR-14 over ROCKY CANYON WASH

Map

Coordinates:
+37.66583, -113.00611
37°39'57" N, 113°00'22" W

Facts

Source: National Bridge Inventory. Information not verified; use at your own risk.
Name:SR-14 over ROCKY CANYON WASH
Structure number:0C 276
Location:3.5 MI EAST CEDAR CITY
Purpose:Carries highway over waterway
Route classification:Minor Arterial (Rural) [06]
Length of largest span:36.1 ft. [11.0 m]
Total length:40.0 ft. [12.2 m]
Roadway width between curbs:27.9 ft. [8.5 m]
Deck width edge-to-edge:33.1 ft. [10.1 m]
Owner:State Highway Agency [01]
Year built:1950
Historic significance:Historical significance is not determinable at this time [4]
Design load:M 13.5 / H 15 [2]
Main span material:Steel [3]
Main span design:Stringer/Multi-beam or girder [02]
Deck type:Concrete Cast-in-Place [1]
Wearing surface:Bituminous [6]

Latest Available Inspection: March 2017

Good/Fair/Poor Condition:Fair
Status:Open, no restriction [A]
Average daily traffic:2,090 [as of 2014]
Truck traffic:15% of total traffic
Deck condition:Fair [5 out of 9]
Superstructure condition:Fair [5 out of 9]
Substructure condition:Fair [5 out of 9]
Structural appraisal:Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck geometry appraisal:Meets minimum tolerable limits to be left in place as is [4]
Water adequacy appraisal:Basically intolerable requiring high priority of corrrective action [3]
Roadway alignment appraisal:Equal to present desirable criteria [8]
Channel protection:Bank protection is being eroded. River control devices and/or embankment have major damage. Trees and rush restrict the channel. [5]
Pier/abutment protection:Navigation protection not required [1]
Scour condition:Countermeasures have been installed to mitigate an existing problem with scour. [7]
Sufficiency rating:63.0

Previous Inspections

DateConditionDeckSuperstructureSubstructureADTSuff. Rating
March 2017FairFairFairFair209063.0
March 2015FairFairFairFair150540.0
March 2013FairFairFairFair178952.4
March 2011FairFairFairFair178052.4
February 2009FairFairFairFair178052.4
April 2007FairFairFairFair155953.8
April 2005FairGoodSatisfactorySatisfactory155970.9
March 2003FairGoodSatisfactorySatisfactory155970.9
March 2001FairGoodSatisfactorySatisfactory147065.8
February 1999FairGoodSatisfactorySatisfactory147065.8
February 1997FairGoodSatisfactorySatisfactory126066.9
February 1995FairGoodSatisfactorySatisfactory126072.4
February 1993FairGoodSatisfactorySatisfactory112573.0
March 1991FairSatisfactorySatisfactorySatisfactory108572.1

Element Data

Source: National Bridge Elements dataset, 2019 edition. This feature is experimental.
ElementUnitsQuantity1-Good2-Fair3-Poor4-Serious
Superstructure
Steel Girder/Beamlinear ft.1880178100
Deck
Reinforced Concrete Decksq. ft.1,320934306800
Substructure
Reinforced Concrete Abutmentlinear ft.66051150
Joints
Pourable Jointlinear ft.6500065
Bearings
Fixed Bearingeach1001000
Bridge Rail
Steel or Aluminum Bridge Raillinear ft.7676000
Reinforced Concrete Bridge Raillinear ft.2020000